First, prepare before starting the machine
1. Whether the joints of the inspection equipment are sealed, whether there is any air leakage (requires the raw material belt and PVC glue to be sealed at each joint); whether the explosion-proof plug is tight (must be tight); check the water supply to the equipment Fill the tap water and cover the lid.
2, the amount of raw materials (from this operation began to bring rubber gloves):
(1) The industrial sodium chlorate and water are mixed at a mass ratio of 1:3, and stirred until completely dissolved, to obtain a sodium chlorate solution (concentration: about 31%).
(2) Industrial hydrochloric acid (concentration 32%), mainly supplied by the manufacturer, has been configured to a concentration of 31% to 32%.
Second, boot
1. Open the ejector: Open the valve of the air inlet and the valve of the air outlet, close all other valves; open the water valve connected to the ejector to make the ejector work normally.
2. Adding sodium chlorate solution: Insert the snake skin tube into the pipette of the sodium chlorate solution storage tank and insert it into the sodium chlorate solution (try to make the container of sodium chlorate solution too high to use the equipment to suck Medicine); open the aspiration valve on the sodium chlorate solution tank and close the inlet valve. At this point, the sodium chlorate solution is slowly sucked into the storage tank until the liquid level of the sodium chlorate solution reaches about two-thirds of the stop from the level gauge.
3. Stop: Open the air inlet valve and open the intake valve of the sodium chlorate solution storage tank. Close the aspiration valve of the sodium chlorate solution tank.
4. Addition of hydrochloric acid: Insert the snakeskin tube into the hydrochloric acid tank near the liquid absorption of the hydrochloric acid storage tank (try to make the hydrochloric acid tank too high to facilitate the suction of the equipment.) Open the suction valve of the hydrochloric acid storage tank and start to open The ejector valve, at this point will see hydrochloric acid slowly sucked into the tank until the level of hydrochloric acid is seen from the level gauge to about two-thirds stop.
5. Stop: Open the inlet valve, open the inlet valve of the hydrochloric acid storage tank, and close the suction valve of the hydrochloric acid storage tank.
6, the use of the pump: turn on the power, turn on the power switch, this is the power indicator light, the temperature controller starts working, set the temperature 40 degrees, dial back the measurement. The equipment starts to automatically heat up (the temperature is no longer set); open the sodium chlorate solution valve, the hydrochloric acid valve (behind the equipment storage tank); adjust the flow regulating valve on both metering pumps to 100%, unscrew the two Metering pump exhaust valve.
7. Hydrogen chloride pump operation: Run the sodium chlorate pump on the control panel. This is the metering pump to start dosing. When the metering pump's exhaust pipe only has the medicine and no air bubbles, close the metering pump exhaust pipe valve, then Slowly adjust the metering pump flow valve to about 30%.
8. Hydrochloric acid pump operation: The amine hydrochloric acid pump runs on the control panel. This type of metering pump starts to add medicine. When the metering pump's exhaust pipe only has medicine and no air bubbles, close the metering pump exhaust valve and then the metering pump. The flow valve is slowly adjusted to about 30%. The chlorine dioxide generator begins to operate normally. (The metering pump flow can be adjusted according to the actual number of chlorine dioxide required).
Third, shut down
Turn off the metering pump switch, the equipment stops feeding, and the ejector continues to work for 1-2 hours, or see the aqueous solution in the ejector whiten, turn off the tap water and power.
Fourth, equipment cleaning
The equipment is cleaned once every day for 2-3 months. When cleaning, turn off the power of the control cabinet and the metering pump switch. The rest is the same as the state when the machine is turned on. A certain amount of water is sucked in from the air inlet, then the power source is turned off, and the drain valve is drained. Cycle this several times until it is clean.
Five, matters needing attention
1. Before the first operation, sufficient water must be added to the equipment, and it is strictly forbidden to operate empty.
2. The metering pump stops feeding. The ejector should continue to work for more than one hour, so that the LV gas in the reactor is fully evacuated to prevent gas from overflowing from the inlet pipe.
3. If the power source suddenly stops water, immediately shut down the running equipment.
4, hydrochloric acid is a strong acid, the operator should wear protective gloves, the raw material NaCl03 is prohibited from being stored together with various acid products and away from fire;
5, equipment temperature control water tank should always replenish water to prevent damage to the heater, the controller is equipped with a protection device, when the water tank water is lower than the set value, the fault light on the control cabinet is bright, should immediately replenish water;
6. Regularly clean the sediment in the reactor. If the liquid level of the reactor liquid level tube shows that it exceeds the normal limit, it means that the sediment is too much, it should be washed immediately; and check the quality of the raw materials.
7. The metering pump tube and ejector are easy to block when the raw materials contain impurities, and should be cleaned and dredged.
8. This equipment is heated by water bath. When the equipment is not in use, please remove the water reaction from the drain valve and the drain valve respectively to prevent freezing when the temperature is below 0 degree and damage the equipment. If the equipment is used intermittently, temperature control can be maintained to prevent the heated water from freezing.